Search   Start
 
 
   
Technical specification
  Measuring values   Actual volumetric flow rate; actual accumulated volume; gas velocity; velocity of sound in gases  
  Measuring principle   ultrasonic transit time difference  
  Maximum flow rate   400 ... 100 000 m³/h (14 125 ... 3 531 467 ft³/h); depending on nominal width  
  Repeatability   < 0.1 % of reading  
  Typical uncertainty   1 measuring path: +/- 2.0 %
2 measuring paths: +/- 1.0 %
4 measuring paths: +/- 0.5%, +/-0.2 % after high pressure calibration
(with straight inlet/outlet section 10D/3D or 5D/3D with flow straightener)
 
  Number of measuring paths   1, 2 or 4  
  Measured gas pressure   0 ... 250 barg (3625 PSI), up to 450 barg ( 6526 PSI) on request  
  Measured gas temperature   -30 ... +180 °C (-22 °F ... +356 °F), -194 °C ... +280 °C (-317 °F ... +536 °F) on request  
  Explosion protection   Europe (ATEX):
- II 1/2 G EEx de ib [ia] IIA T4 or II 1/2 G EEx de ib [ia] IIC T4
- ultrasonic transducers are intrinsically safe "ia"
USA/Canada (CSA):
- Class I, Division 1, Groups D T4; Class I, Division 2, Groups D T4
- Class I, Division 1, Groups B, C, D T4; Class I, Division 2, Groups A, B, C, D T4
- ultrasonic transducers are intrinsically safe "ia"
 
  Measured value output   HF pulse (NAMUR or Open Collector); 4 ... 20 mA (active/passive); insulated  
  Interfaces   Modbus ASCII (RS485) and Modbus RTU (RS485): configuration, measured values, output and diagnosis or
HART: configuration, measured values, output and diagnosis
 
  Installation length   3D/5D, 150 ... 2400 mm, depending on nominal size  
  Nominal size   DN 50 (2") ... DN1200 (48")  
  Material   meter size < or = DN600/24":
steel 1.1120 / ASME A216 WCC; stainless steel 1.4408 / ASME A351 Gr. CF8M
meter size > DN600/24":
steel 1.1120 / ASME A216 WCC, flanges ASTM A105; stainless steel 1.4408 / ASME A351 Gr. CF 8M, flanges 1.4404 / A182 Gr. F316L
 
  Remarks   Options can be delivered as special versions on request.